The Guide to Film Viewer Selection

A Guide to Film Viewer Selection.

The purpose of this guide is to help the reader make an informed decision when purchasing a new Film Viewer. Considerations include: Light Source, Intensity, Density, Moisture / Environment, Size & Portability, and Cost.

Light Source

LEDs are now the preferred lighting soure for industrial x-ray film viewers, as they produce a bright, uniform luminance that is perfectly suited to x-ray film viewers.

Historically, incandescent lamps such as photo-floods, were used as a light source that produce more heat than light. Viewers were large and heavy to accommodate cooling. They ran hot, and bulbs burned out frequently.

Over the years, other light sources (such as quartz halogen projector bulbs) have been used that offered some nominal improvements. Compact fluorescent tubes were introduced in the past decade. They were a breakthrough, as they produced little heat and allowed illuminators to be made more compact.

In addition to LEDs pure white light, the life expectancy of LEDs is around 40,000+ hours, eliminating the need to stock spare incandescent bulbs that are becoming more expensive, harder to find, and eventually will become obsolete.

LEDs produce virtually no heat, so LED Film Viewers can be made much more compact since there is no need for a large fan. Plus, the distance of the LED to the viewer screen is much less than that required for incandescent lamps. For example, a 14″x17″ viewer that used to have an approximate depth of 12 inches is now approximately 4 inches.

Uniformity of illumination is greatly improved as LEDs are distributed evenly across the viewer window. Therefore, the intensity near the edges of the view window is more similar to the intensity in the center of the window.

Intensity

Brightness / Illuminance

The needed brightness depends on the density of film you need to view. In calculating the intensity requirement, maximum film density is often spec’d at 4.0 D , which requires 100,000 candela/cm2 of luminance (see table in next tab labeled Density).

Since LEDs will dim as they age and as a function of how they are used*, we recommend a viewer that is 1.5-2x brighter than required. This will put less stress on the LEDs, and even if the LED does age, you should have sufficient reserve intensity to compensate for many years.

*Operating a viewer rated at 200,000 candela/cm2 @ 100,000 will have a greater expected life expectancy than running a viewer rated at 100,000 candela/cm2.

In other words, even though LED’s are rated to 40,000+ hours, if you use your viewer running it at maximum intensity for long periods of time, you may need to change the LED board in 3-5 years.

Density

Film viewers should have the intensity to read a 4.0 density film (according to many common specifications). *

Luminance is the brightness of a surface such as a PC monitor or Film Viewer. **
Current specifications require x-ray film viewer intensity to measure in Luminance. The recognized scale is cd/m2 (Candela / meter2). ***

The following are the current requirements:

    1. Measuring films having a density lower than 2.5 requires Luminance greater than 30 cd/m2 (measured through the film).
    2. Measuring films having a density greater than 2.5 requires Luminance greater than 10 cd/m2.
    3. The above means that your film viewer should have the following minimum luminance value:

density-intensity.jpg

Note: Measuring Luminance requires a Luminance Meter. Note: Conventional Light Meters measure Illuminance not Luminance. There is no conversion possible between Ft/ Candles or Lux (which are measurements of illumination and µw/cm2, which is a measure of luminance.

 Luminance vs Illuminance

Many people are not familiar with the difference between luminance and illuminance. These are two different systems.

Luminance: The brightness of a surface such as a viewer or computer monitor.
Luminance is measured in Candela/cm2 or Foot Lamberts.

Illuminance: The brightness at a distance from the source.
UV lamps are typically required to have 1,000 µw/cm2 at 15″.

A conventional light meter is designed to measure illumination in ft. candles or lux.
These light meters cannot be used to measure a film viewer, because there is no conversion factor.
A luminance meter is required. Example: Spectronics AccuMAX Luminance Meter with XS-555 Visible Luminance Sensor.

* FIG 1 of ASTM-E-1742 indicates 4.0 density requires 100,000 candela/m2
** Illuminance is used to measure lighting intensity such as UV and White Light lamps. There is no conversion possible for Luminance to Illuminance.
*** Illuminance values (Foot candles and/or LUX) for measuring Luminance is no longer recognized.

Moisture / Environment

What is the environment where you would use your illuminator?

Could the conditions be somewhat wet? An example might be a mobile darkroom. Are you viewing wet film? If so, you run the risk of voiding any warranty on any viewer not specifically designed for wet use. Older style viewers (Photo Flood type) are more tolerant of moisture than LED viewers that have sensitive electronic circuitry.

We offer Drip guards for some viewers to minimize the risk of getting water into the viewer. It does not protect from chemical fumes that cause oxidation and chemically attack the electronics and structure of the viewer. Water and chemical damage is not covered by warranty.

Viewers made with stainless steel housing and hardware will withstand the corrosive environment present inside a dark room. Sealed viewers are also preferred for this application.
The LCNDT FV-2009 PRO &  Kowolux M1 and M2 are our suggested viewers for use in wet conditions.

Size & Portability

What size film do you need to view?

It is important to think about this before deciding on a viewer. The viewer window should be large enough to minimize the need to move the film, while being compact enough for the space allocated.

If you are traveling with the viewer consider one of the compact and light weight LED Viewers offered.

LED viewers with large viewing areas used to be cost prohibitive; they are now more affordable.

You should select the size to fit your needs and budget.

Do you need portability, and to what degree?

LED and compact fluorescent viewers are smaller and lighter than conventional Viewers. The strip film viewers (on the left hand column of the Strip Viewers and LED Light source page) are the most portable Viewers available. The FV-2009 Plus is the one of the most compact and battery operated.

Cost

Cost vs Quality?

Just like with automobiles, film viewers vary in quality. Some differences  you can see and experience immediately, while others may become apparent over time. For instance, some brands of viewers seem to have less of an issue with LED aging.

Some manufacturers may apply a higher voltage to the LED to maximize intensity instead of using a higher intensity LED. If a user consistently runs these viewers at maximum intensity, the LED’s will dim over time.

        • Ask us which viewers are more conservatively rated.
        • Buy a viewer that is rated ~ 150% brighter than you need and operate it at the lowest intensity that will get your job done.

Join NDT Supply and OKOndt at the RI 2023 Exhibition, October 1st – 4th

NDT Supply, together with OKOndt, will take part in the RI 2023 exhibition (REMSA section). This is the largest railroad show in America, with more than 10,000 railroad workers due to attend.

We invite you to visit our booth No. 4055 October 01-04, 2023. The event will take place at the Indiana Convention Center (Indianapolis, Indiana), where specialists from our companies will be happy to welcome you and discuss issues related to non-destructive testing on the railroad. OKOndt will be presenting their latest developments in the field, including presentations for the popular the UDS2-77 RSUI Ultrasonic Rail Flaw Detector and the OCOSCAN 73HS Series.

Fraud Alert: Scammers Impersonating NDT Supply

Please be aware that scammers have illegitimately tried to recruit candidates saying they are hiring for a position in our company. We would never conduct text-based interviews nor request personal data or private financial information during the interview process.

Please see following link for more information on this type of scam and how to protect yourself: FBI Warns Cyber Criminals Are Using Fake Job Listings

ETher WeldCheck + AeroCheck: Rapid Delivery, Top-Quality Warranty

The Very Best in Eddy Current Performance, Now with Impressive Delivery Turnaround Times

Rapid Delivery

ETher NDE can confirm that all their Eddy Current Flaw Detectors are now available with delivery “Ex-Stock”, including the WeldCheck and AeroCheck Phase Plane Instruments. Plus, most of ETher’s standard Probes & Accessories are now being delivered within a few days.

3 Year Warranty

Receive your flaw detector before the rest and enjoy ETher’s 3 Year Warranty, which includes all Replacement Parts and Labor Costs (customer damage excluded). Although the 3 Year Warranty comes standard, you can also opt in for an extended 6-year ETherCover warranty plan, putting it truly in a league of its own.

Order Now - Discounted during July only!

Available in Single and Dual Frequency models, the AeroCheck Flaw Detectors deliver the best in Eddy Current performance, with rotary inspection capabilities as standard, together with variety of advanced features.

Appeals to users across a wide range of sectors including Offshore, Rope Access, Infrastructure NDT applications, plus other weld inspection requirements replacing MPI and LPI, especially on coated welds.

On Sale Now! 10% Off AccuPro Series

Spectro-UV AccuPro XP-2000 and
XP-4000 10% off, only until June 3rd!

Don’t miss this great deal on a great product

AccuPro Series meters feature an advanced, microprocessor-controlled readout unit calibrated to accurately measure and display UV-A, Blue and Visible Light readings.

These compact, lightweight, battery-operated units are ideal for use in the field, the factory or anywhere accurate light measurements are needed.

Click here for more information on the AccuPro Series and to purchase

Unique Ultrasonic Concrete Testing Equipment for Prevention of Catastrophic Failures in Concrete Structures

We are all aware of the catastrophic failure of a Condo building outside of Miami. Failure appears to be related to defective concrete construction and deterioration, leading to an increased demand for tools to inspect concrete structures.

ACS offers unique ultrasonic concrete testing equipment that can detect defective concrete. Some of their products are fairly simple and relatively inexpensive, such as the A1410 Pulsar and UK1401 Surfer.

These devices measure the velocity and intensity of through transmitted low frequency ultrasound. Good quality concrete has faster transit time with less attenuation (loss) of sound. Absolute values can be measured or items compared to known good structures.

The other devices are imaging systems that can display rebar, voids, indicate thickness, etc.

Please look over Ultrasonic Concrete Testers on our website and contact us with any questions.